Air Conditioner Remote Control, Indoor Temperature Sensor
|
Core data |
Resistance value | R25=10KΩ±1% | Operating temperature range | -20℃~100℃ |
| B value | B25/85=3435K±1% | Maximum rated power | 187mW | |
| Thermal time constant | ≤20s | Pressure resistance | N.A. | |
| Thermal dissipation coefficient | ≥2.5mW/°C | Insulation properties | DC 500V 1s Insulation resistance≥100MΩ |
Located at the air outlet of the indoor unit, it detects indoor temperature to control the air conditioner's operation. When the indoor temperature reaches the set requirement, the air conditioner automatically adjusts its operating state. For example, in cooling mode, the outdoor unit stops while the indoor fan continues running; in heating mode, the air conditioner automatically adjusts fan speed to ensure comfort.
|
Core data |
Resistance value | R25=19.400~20.600KΩ | Operating temperature range | -15℃~50℃ |
| Bvalue | B25/50=3950K±2% | Maximum rated power | 85mW | |
| Thermal time constant | ≤3.5s±1.5s | Pressure resistance | AC 1800V1s, Leakage current≤1mA | |
| Thermal dissipation coefficient | ≥3.4mW/°C | Insulation properties | DC 500V 1s Insulation resistance≥100MΩ |
Located on the rear fins of the outdoor unit, it detects the ambient outdoor temperature to regulate the operating speed of the outdoor unit. During cooling or heating cycles, it adjusts the air conditioner's operating mode based on the outdoor temperature.
|
Core data |
Resistance value | R25=10KΩ±2% | Operating temperature range | -40℃~100℃ |
| B value | B25/50=3950K±2% | Maximum rated power | 410mW | |
| Thermal time constant | ≤10s | Pressure resistance | AC 1800V1s,Leakage current≤1mA | |
| Thermal dissipation coefficient | ≥5.5mW/°C | Insulation properties | DC 500V 1s Insulation resistance≥100MΩ |
Located at the air outlet of the indoor unit, it detects indoor temperature to control the air conditioner's operation. When the indoor temperature reaches the set requirement, the air conditioner automatically adjusts its operating state. For example, in cooling mode, the outdoor unit stops while the indoor fan continues running; in heating mode, the air conditioner automatically adjusts fan speed to ensure comfort.
|
Core data |
Resistance value | R25=20KΩ±3% | Operating temperature range | -40℃~105℃ |
| B value | B25/50=3950K±2% | Maximum rated power | 260mW | |
| Thermal time constant | ≤5s | Pressure resistance | AC 1800V1s,Leakage current≤1mA | |
| Thermal dissipation coefficient | ≥3.5mW/°C | Insulation properties | DC 500V 1s Insulation resistance≥100MΩ |